The range of voltage stabilizers is rather narrow and covers only network models up to 1 kW power. Manufacturer Country: PRC.
The maximum input voltage range is organic frames 150-280V.
Main appointment: Audio, video and video protection computer equipment From the voltage jumps in the network, pulse interference. Very particular can be found on the radio rolls, various hypermarkets of Eldorado format or technostyle.
Model range of voltage stabilizers Defender:
AVR IPOWER 600/1000.
AVR TYPHOON 800/1200.
AVR REAL 600/1000/1500/2000
AVR Initial 600/1000/2000
AVR Premium 600i / 1000i Source: http://www.defender.ru/

Photos of stabilizers Defender.


Reviews of voltage stabilizers Defender

Defender 1000VA. He is very hot, 245 volts at the output, it all starts with a non-operating power button. I hang two such miracles ...
(http://www.rom.by) Defender - a stabilizer cheap and not accurate. And perhaps also on the sound will not affect the better.

It is better to buy a normal network filter. Not Defender. Or connect everything to the UPS ... IMHO, it will be better ...
(http://forum.doctorhead.ru/) Defender Avr iPower 1000VA works for the second month. So far all is well. There are no complaints. As I understand it, the click denotes the fact that there was a voltage drop. We do not click often, but clicks.

Many outlets and long cord

This network filter is not a panacea from all the troubles of course. But the main protection against short circuit and high load is there. Yes, and turn off the general power switch is convenient for my case.
pros: A lot of outlets, there are five of them and everything with a grounded contact (which is positively affected not only on electrical safety, but also to increase the dishevement of the instruments). The linner wire, really saddled across the entire room at 17 square meters. Metrov was enough.
Minuses: And what in such a simple design maybe not so? Is that materials, but they are quite practical here.
(http://abc.ru/) I use Defender for a long time. Not only multifunctional, but also qualitatively. Plus - they are almost in all stores, you do not need to look for something. The site read the specification, chose the right and forth for the purchase. Still moment - affordable price
(http://forum.ru-board.com/)

Does not suit the work of the stabilizer

Acquired a stabilizer Defender Avr Real 1000. With the purchase of this stabilizer, a small error was published, there is an option to return it or change it, on all this case is 14 days. The question is such - the stabilizer is stepped, how should it work? Familiarized with the work of stepped stabilizers. But how it works I do not like it. It is possible to check it only under reduced voltage.
In general, here, how it works - I measure the voltage in the 200 - 205 V. At the output of the stabilizer exactly the same tension. 198 - 200 V. On the network, at the exit - the same. How the voltage in the network becomes below 196 - 197 volts, it begins to stabilize and gives out + - 230 V. I do not like it sharp jump since 196 at 230 volts.
I believe that stores should indicate the principle of operation, such as these devices, since stabilizers are divided by types. I like a person who did not know this miracle, counting on raising the voltage from 200V, which we usually have in the network to + -230 V.
The characteristics says the outlet voltage - 220 V ± 10%. I did not think that he will give me 200 volts. Also, as online and plus this jump from 196 to 230 V.
Explain, maybe something I do not understand how this miracle should work. Why is it only when the voltage reduced on the net (197 - 196 V.) gives 230V, and not at 200 V.? 200V I consider already reduced voltage.
(http://shop.ww.kz/)

Swashing transformer, big error

At home there is a 1000VA defender. About stabilization of special complaints. Fine. Strenage from 160 and up to 240V raises \\ lowers start to 210-230. Of the minuses - a little buzzing transBut this is just an instance of such a caught. Even more customers have 1500VA. The same is fine. Stabilization is based on a high-capacity trance and switching the rest (seemingly). More from the minuses - the windings of these most not so much, the stabilization step of stabilization is relatively large. Plus there is a sense from him if simply the voltage in the network is too low, or in the evenings falls. From strong jumps (for example zipper), protects whether it will actively work too slowly. I would advise if from inexpensive, it is better to take a crawler. More reliable, more turns, better electronics + there is an indicator (voltage) of input voltage and voltage at the output. (at home and such too)
(http://www.forum-volgograd.ru/)

Small transformer size and control board

Defender AVR Premium 1000.
Inside the device is done very ergonomically ... however the quality of execution did not like much.
For example, some wires were shifted between parts of the case, and on the transformer hung a pair of foreign soups of solder, which can easily call a short circuit if you donate.
The transformer itself, placed in the cast fastening, looks frankly small. In any case, its dimensions are noticeably more modest compared to IPPON AVR-1000 and especially from SVEN AVR-1000. This is although indirectly, but quite truthfully talks about maximum power.
The handker with electronics is also small. On it installed one unidentified microcircuit with OMVK2P301 marking, which is most likely a set of several operating amplifiers. The transformer winding switches the three relays YX202-S-112D with a rated current of 10 amperes, which already indicates the minimum number of regulatory steps. Of the pleasant one can note only the presence of enough large varistor against pulse interference.
Examination conclusion: Defender AVR Premium 1000 is a classic voltage stabilizer operating from 160 V. Among all three models, the device is characterized by the lowest power and a weak margin of strength at the highest price.
(http://tech-labs.ru/) After the failure of a single device of household appliances and refusal in warranty repair due to the unstable voltage had to take action, bought Defender AVR Real 600. For TVs and CD players I calm . Although the flickering of yellow and red indicators is often quite it can be seen that not all right with tension!
It is reliable, easy to use, compact, almost Beshume, in 2 years I got out more than once, so I recommend ...
(http://utinet.ru/) I bought myself a system of Defender, and the consultant suggested and take a stabilizer Defender AVR REAL 2000. Since he looked stylish enough and cost cheaply, agreed. At home he just fits perfectly in the interior worked quiet and unnoticed. And then they went raining and crumbled the shield, so in the house a bunch of technician was staring, and I had a working system. Then I read on the Internet that he is not only high voltage Reduces, but also low raises.
(http://odinka.ru)
Advantages: a reliable stabilizer, powerful, I have to him connected system unit and plasma TV With the receiver, everything pulls out, although we have most of the time voltage in the 180-200 V network.
Disadvantages: several times after the disconnection due to the voltage drop, did not want to turn on immediately, apparently did not work the relay, it was possible to turn on only every other day ...
(http://reviewdot.ru)

Stabilizer Defender 1000VA: Review and Feedback

Today I decided to tell about the useful thing - voltage stabilizer.
It is indispensable because even in the largest settlements time, the voltage will jump. Network filter does not share anything with this, all that is in it, these are interference resistors. The stabilizer may in the minimum time to level the voltage or turn off the load at all. Such a stabilizer was purchased with a fridgein order to serve it.
At that time - the 11th year, it was the best that could be found in the non-industrial sector.

    What is this stabilizer in practice?
  1. Sellers sincerely argued that 1 kW of the stabilizer is enough for one compressor. It turned out that there is no. At least it is 1.5 kW. When starting the compressor, often refrigerator Recharged Frost Program and re-started the compressor and so up to 5 times,
  2. At the same time, the stabilizer is frantically skidded and changed the modes of operation from normal to power up mode. Power in 1kW was clearly not enough.
  3. Kosyaki with Defender 1000VA began after several months, but at first they did not pay attention. Frost temperature rises on the refrigerator And after a while again came to normal.
  4. After a year at the output, the stabilizer appeared 200-210 volts instead of the 220, although it was 220 at the entrance. The stabilizer began to bring harm, and not benefit.
  5. After a few days a buzz stabilizer failed. This manifested that he turned on the red light (red indicator) and reported that the voltage was so much beyond the scope of the permissible that it could no longer stabilize it. Repeated good luck attempts did not bring. A few days later, the stabilizer began to work itself again, but for a long time? The network has 260-230 volts stable.
Conclusion: Network filters of the same company also do not differ good quality, now stabilizers too ...
(http://comuedu.ru) there is a stabilizer Defender AVR Real 1500. Everywhere on the Internet read that stabilizers cannot be used with ungrounded outlets..
It works from such a couple of years. But that's what surprises me: on the stabilizer 5 sockets (weekends) and everything without grounding. Just as I already change the 4th ADSL modem for a year and a half (stick to the same stabilizer) ...
(http://electrik.org)

Defender Stabilizer for Sound

After moving to another area there was a problem with nutrition - the voltage often sends, after one such fall the CD player was simply cut off during playback.
It was necessary to wait for a short time - when the relay click and the indicator was notified of work on the boost, the tester showed in the outlet 207 V. Voltage walked from 190 to 212 V, at the output of the stabilizer was from 233 to 240 V.
Listened to the whole disk. During this time, the stabilizer switched three or four times.
On the technique, his work did not affect him, I did not hear in the speakers. Sound degradation, with all your efforts, I did not notice - nor in normal mode, nor in the mode of increasing (on a decrease, the stabilizer worked once during the day, was in this mode for no more than a second, so measurements, psychoacoustic, incl. Make did not have time).
If you do not count the relay clicks, device silent, hear the buzz of transformers can be if attached an ear to the case.
At the same time, the stabilizer is quite noticeable, the floor has grown under it. It is uncomfortable, in my opinion that the button on the front panel does not turn off the device from the network - the stabilizer continues to climb the relay, but no indication.
As a result, I can recommend Defender Avr Real for budget decisions - I do not think that on such systems you can hear the negative impact of such stabilizers on the sound - without fanaticism and the technique is not scary.
(http://electrik.org) Standard voltage stabilizer, in its characteristics closer to pilots. There will be no special procuer from it with serious voltage fluctuations, but in the case of small deviations, it is completely worn.
(http://utinet.ru)

- August 5, 2016

Burned after 6 days of use. Only the refrigerator was connected. The sound broke the relay (I can and wrong).

Advantages:

Availability of 2 sinks, wires and switch :)

Disadvantages:

Low quality.

Use period:

less than a month

6 12
  • Matrosov Georgy.

    - December 24, 2016

    I consider it ideal for the TV.

    Advantages:

    Excellent stabilizer for TV. Quickly switches when the voltage is reduced. Not buzzing. Compact. It has been working for almost 4 years.

    Disadvantages:

    Little sockets.

    Use period:

    more than a year

    1 0
  • Bearing Arsenal

    - June 12, 2017

    Bought 1.5 years ago two pieces \u003d normal flight!
    Passage B. best of sight!

    Advantages:

    All super!

    Disadvantages:

    Use period:

    more than a year

    1 1
  • Mitrofanov Aleksey

    - July 23, 2017

    Output voltage range completely ...

    Advantages:

    Easy, compact.

    Disadvantages:

    Before indefinitely, a short network cord. There is no voltmeter (here is a reservation: it is better to let it be at all, than it is imitation - with the constantly displayed value of "220 V", as for the low-minded. Standed on the Yandex Market with a 1000 W Power is erroneous. This is the model number. In the original instruction The active power is indicated as 320 W maximum. With usually received cos f \u003d 0.7: 320 / 0.7 \u003d 457 VA, we accept the nearest - 500 wa. not 1000!

    Use period:

    less than a month

    1 0
  • Mitrofanov Aleksey

    - July 25, 2017

    Advantages:

    Easy, compact.

    Disadvantages:

    Before indefinitely, a short network cord. There is no voltmeter (here is a reservation: it is better to let it be at all, than it is imitation - with the constantly displayed value of "220 V", as for the low-minded. Standed on the Yandex Market with a 1000 W Power is erroneous. This is the model number. In the original instruction The active power is indicated as 320 W maximum. With usually received cos f \u003d 0.7: 320 / 0.7 \u003d 457 via. And if we consider that the manufacturer indicated the rated current of 1.3 A, then the power: p \u003d u * i * COS F \u003d 220 * 1.3 * 0.7 \u003d 200 VA. Even at the maximum, at a voltage of 240V and working with a heating instrument (COS F \u003d 1): P \u003d 240 * 1,3 \u003d 312 ...

    Use period:

    less than a month

    0 0
  • Kovalev alexander

    - November 4, 2018

    It works from 2010 until now, one time in a pair with a refrigerator, then with TV. Quiet, sometimes when the voltage drops are heard, of course, the relay is triggered, but in normal mode in terms of noise almost not heard. I can simply compare ...

    Advantages:

    Reliability (working from 2010)
    Low noise

  • Bearing Arsenal

    Advantages: everything is super!

    Disadvantages: No.

    Comments: Bought 1.5 years ago two pieces \u003d normal flight! Pass at best!

    Mitrofanov Aleksey

    Experience: For several years.

    Advantages: Easy, compact.

    Disadvantages: Before indefinitely, a short network cord. There is no voltmeter (here is a reservation: it is better to let it be at all, than it is imitation - with the constantly displayed value of "220 V", as for the low-minded. Standed on the Yandex Market with a 1000 W Power is erroneous. This is the model number. In the original instruction The active power is indicated as 320 W maximum. With usually received cos f \u003d 0.7: 320 / 0.7 \u003d 457 VA, we accept the nearest - 500 wa. not 1000!

    Comments: The output voltage range fully complies with GOST: 220 V +/- 10%. This means that there will be no "improvement" of the voltage to the device. But if there are deviations in a large or smaller side - it copes perfectly. Checked the LATR: it turns off exactly as stated by the manufacturer 175 and 285 (!) B. Better is suitable for high voltage. Stabilization begins to work after 240 V - clicks the relay and the voltage drops (sharply! It is hardly frequent, such a decrease is useful) to 211 V. at 262 \u003d\u003e 230, at 274 \u003d\u003e 240V. In general, I liked it.

    Experience: For several years.

    Advantages: Easy, compact.

    Disadvantages: Before indefinitely, a short network cord. There is no voltmeter (here is a reservation: it is better to let it be at all, than it is imitation - with the constantly displayed value of "220 V", as for the low-minded. Standed on the Yandex Market with a 1000 W Power is erroneous. This is the model number. In the original instruction The active power is indicated as 320 W maximum. With usually received cos f \u003d 0.7: 320 / 0.7 \u003d 457 via. And if we consider that the manufacturer indicated the rated current of 1.3 A, then the power: p \u003d u * i * COS F \u003d 220 * 1.3 * 0.7 \u003d 200 VA. Refrigerator, with its starting current, three times large nominal, will definitely not pull.

    Comments: The output voltage range fully complies with GOST: 220 V +/- 10%. This means that there will be no "improvement" of the voltage to the device. But if there are deviations in a large or smaller side - it copes perfectly. Checked the LATR: it turns off exactly as stated by the manufacturer 175 and 285 (!) B. Better is suitable for high voltage. Stabilization begins to work after 240 V - clicks the relay and the voltage drops (sharply! It is hardly frequent, such a decrease is useful) to 211 V. at 262 \u003d\u003e 230, at 274 \u003d\u003e 240V. In general, I liked it.

      Absolutely silent, worked for more than three years and I don't even bother that something can happen, inspires a huge trust, compact about the fact that it is not just a filter and the stabilizer, watched the price on the Internet so he from the moment of purchase only went up, weighty - it means not Dummy, I think the assembled of worthy components.

      A year ago

      Delived to free, compactness, 2 outlets.

      A year ago

      Reliability (working from 2010) Low noise

      2 years ago

      Excellent stabilizer for TV. Quickly switches when the voltage is reduced. Not buzzing. Compact. No smell. It has been working for almost 4 years.

      2 years ago

      it works reduces the voltage from 238 to 210. It was not necessary to increase the increase.

      2 years ago

      Compact and not noise. There are no advantages.

      3 years ago

      Easy, compact.

      3 years ago

      All super!

      4 years ago

      Availability of 2 sinks, wires and switch :)

      I would like more plug-in devices, but the outlet of the outlet is only two, however, I consider it a small minus (even I would say the design feature), it happens when the characteristic click will be triggered at night, but also for more than three years I used to What is in big minuses and no!

      A year ago

      Weak (about 300 Vs), only 3 steps 1 down, 2 - up, at 173 in the defense goes, although at the output of 203 V, i.e. too early. No protection against overload, no voltmeter (s). Well, in fact, this is not a stabilizer.

      A year ago

      No was detected

      2 years ago

      Little sockets.

      2 years ago

      Disturbing gullible buyers in the store, in the name of 1000. Wow 1000 W & AN no one 320. The relay snaps loudly when switching to stabilization mode, moreover, this happens if the voltage jumps from 233 to 239 reminds the rosary of the annoying grasshopper. At the same time, the following happens: at the inlet 239 at the output 210 at the input 233 at the output 233 Stabilization is turned off, I think that household appliances Do not like such races.

      2 years ago

      I bought pursuit of the stabilization of 220 + 10%, that is, for example, 199-200 and he must raise 10% in an idea to about 220V. In reality, he does not care, the voltage in the network walks from 180 to 218, usually 195 - this stabilizer does not stabilize anything at these levels - zero! After that, the CyberPower CP1500EavrLCD is connected to the computer to the computer, so it immediately reacts and starts stabilize from 200V, increasing to normal levels and showing the incoming voltage that comes from this so-called "stabilizer" for 2500r ....

      3 years ago

      Before indefinitely, a short network cord. There is no voltmeter (here is a reservation: it is better to let it be at all, than it is imitation - with the constantly displayed value of "220 V", as for the low-minded. Standed on the Yandex Market with a 1000 W Power is erroneous. This is the model number. In the original instruction The active power is indicated as 320 W maximum. With usually received cos f \u003d 0.7: 320 / 0.7 \u003d 457 via. And if we consider that the manufacturer indicated the rated current of 1.3 A, then the power: p \u003d u * i * COS F \u003d 220 * 1.3 * 0.7 \u003d 200 VA. The refrigerator, with its start current, three times large nominal, will uniquely not pull. Does not correspond to the declared parameters (voltage operating range).

      3 years ago

      4 years ago

      Today's life is difficult to imagine without high-tech devices. And each of them is one way or another has a dependence on the power supply. From the largest like a refrigerator, to the smallest in the form of smartphones and other gadgets. Well, about the laptop or desktop PC in general, there can be no speech. If the laptop is thin poorly protected from differentials and jumps on the network, and most likely the power supply itself, and not the system itself, then in the case of the desktop PC, the result is likely to be sad.
      I think you should not repeat the course of physics and talk about possible troubles that may arise in power networks. There are practically no ideal household networks in general, and in the event of Russia the situation is more complicated. Any socket and an electrical appliance carry a potential danger, and if in the case of a short circuit of the wiring, it all depends on objective factors, then in terms of the electrical network itself, both rare interruptions and frequent, leading to damages of sensitive high-tech equipment can be. The most simple I. affordable way Avoid this is voltage stabilizers. This is a relatively affordable way of protection, the benefits of using is obvious. Today we will look at Defender AVR Premium 1000i.

      Two models are available in this line - 600i and 1000i, the main difference is output power. This is the second generation of stabilizers of this line, the case has changed, small changes have been made, in general, the filling remained unchanged. The principle of operation is to automatically hold the voltage level at the level of optimal, compensating for the increase or decrease in the power grid. In the case of a critical increase, there is a smooth disabling of the equipment from the network.

      Accessibility Defender AVR Premium 1000i

      At the time of testing, the cost of Defender AVR Premium 1000i is at the level of 1,270 rubles.

      The price is very democratic, it is one of the most affordable voltage stabilizers on russian market. Price tag comparable with average for high-quality network filters. When choosing a nutritional organization for PC, I would prefer precisely stabilizers, and not filters. In the case of the latter, it is very easy to obtain an ordinary extension with one fuse inside the case, we have convinced already in this with a massive testing of network filters with a price tag below 500-800 rubles.

      Equipment Defender AVR Premium 1000i

      The voltage stabilizer comes in a compact package with an image of the device on the glands of packaging and brief specifications.

      Actually, except for Defender AVR Premium 1000i itself there is a warranty card, instruction and a copy of the certificate of accordance with GOST. This is enough to start work.

      Appearance Defender AVR Premium 1000i

      On the front panel there are three LED indicators with several illumination variants depending on the conditions in the incoming and outgoing network.

      Each plot is signed, it is AVR, Normal, Overload. The company on this face is the company's logo.

      On the back of the integrated power cord and the power button.

      4 outlets are bred from above, two in two rows. This is Euro.

      Externally, everything is simple and logical. Case made of gray plastic with matte coating.

      In the lower part there are legs and slits to remove warm air.

      Filling Defender AVR Premium 1000i

      Inside, everything is organized ergonomically, all space is used with maximum benefit. All wires are neatly folded inside the housing. Under the ventilation grids, a transformer is located in a special compartment with fasteners. The size corresponds to the maximum power.

      You can also note the availability of fees with electronic components. There is a large varistor that protects against impulse interference.

      In conclusion, I will note the presence of three relays with a current 10a. No complaints and comments in the framework of I have no knowledge in this area.

      Made everything really kindly.

      Testing Defender AVR Premium 1000i

      Testing a voltage stabilizer Defender AVR Premium 1000i comes out of the framework of the usual sets of tests adopted in our laboratory. Unfortunately, the class of such devices itself is quite rare guests on tests, so while it is not compared with what the data obtained I will compare with optimal in this segment. I closure, I liked the tests yourself, and I will try to consider other models from this manufacturer in the future, as well as competitive solutions.

      We proceed, to begin with, we check how the stated characteristics correspond to real. To do this, create artificial changes in the input voltage and measurements both at the inlet and at the output. I use the device with the output output on the display, such data can be considered more accurate than the use of traditional equipment.

      Defender AVR Premium 1000i copes with his direct task to excellent. The minimum stable bar is fixed at 160V, according to this parameter, everything corresponds to the declared within ± 10%. With a further decrease, an automatic shutdown occurs. Table 1 (input / output) (160 - 200, 180 - 224, 190 - 214, 200 - 223, 210 - 215, 220 - 220, 230 - 226, 240 - 234, 250 - 216)

      During switching, the deviation winding is not recorded. The work is smooth, any problems are not fixed by neither increasing, nor by lowing nutrition.

      So it turned out, but I used this stabilizer to publish the test every day for 3 months, the problems were not fixed. All this time to the stabilizer Defender AVR Premium 1000i was connected test stand Laboratories, as well as small household appliances, charging phones, second home PC. During problems in the household network, the work of the stabilizer is accompanied by clicks, everything else is completely silent.

      At the end of the test it is necessary to measure operating temperature. This is an indirect sign, indicating the fault tolerance and durability of the stabilizer itself. During domestic use, the temperature in the hottest part does not exceed 50 degrees, it is quite low.

      Video Review Defender AVR Premium 1000i

      Results by Defender AVR Premium 1000i

      Defender AVR Premium1000i. Changes with its task for excellent. Budget value with declared decent characteristics, a strong assembly and a wide range of operating voltage - that's what I can say about this solution. Some weighty and significant disadvantages are hardly allocated, which can be wished if only the presence of an LCD display with the display of the incoming and outgoing voltage. But if it needs to be an ordinary user, a big question, the main thing is that this compact box performs its direct responsibilities.

      I personally for myself practical use And field tests made an unequivocal choice in favor of using household voltage stabilizers.

      Defender AVR Premium 1000i gets a reward - "Gold..



    Did you like the article? Share it